Modify ↓
Ticket #15 (closed defect: fixed)
megaraid-status shows an error when a hotspare disk
| Reported by: | sistemas@… | Owned by: | gandalf |
|---|---|---|---|
| Priority: | major | Milestone: | 1.0.0 |
| Component: | packages | Version: | |
| Keywords: | megaraid-status | Cc: |
Description
When I run megaraid-status, it shows this:
-- Arrays informations -- -- ID | Type | Size | Status a0d0 | RAID 5 | 272GiB | optimal -- Disks informations -- ID | Model | Status | Warnings a0c0t0 | SEAGATE ST373207LC 68GiB | online a0c0t1 | SEAGATE ST373207LC 68GiB | online a0c0t2 | SEAGATE ST373207LC 68GiB | online a0c0t3 | SEAGATE ST373207LC 68GiB | online a0c0t4 | SEAGATE ST373207LC | hotspare a0c0t5 | SEAGATE ST373207LC 68GiB | online There is at least one disk/array in a NOT OPTIMAL state.
The hardware is a Dell PowerEdge 2850 with a Dell PowerEdge Expandable RAID Controller 4e/Di (using megaraid_mbox kernel module LSI Logic MegaRAID driver). The software is a Debian GNU/Linux 5.0.3.
The problem is that it sends e-mails warning about that condition, which I thinks that is not necessary.
Many for this site and for this debian repository which is thruthfully needed.
Rafael J. Alcántara Pérez <sistemas@…>
Attachments
Change History
Changed 2 years ago by sistemas@…
-
attachment
megaraid-status.diff
added
Note: See
TracTickets for help on using
tickets.


Patch to fix the bug