  • LSIMegaRAIDSAS

    v13 v14  
    103103{{{
    104104server:~# megacli -AdpAllInfo -aAll
    105 
    106105Adapter #0
    107106
     
    131130}}}
    132131
     132Logical drive 0 on adapter 0 status and type:
     133{{{
     134server:~# megacli -LDInfo -L0 -a0
     135Adapter 0 -- Virtual Drive Information:
     136Virtual Disk: 0 (Target Id: 0)
     137Name:raid1
     138RAID Level: Primary-1, Secondary-0, RAID Level Qualifier-0
     139Size:237824MB
     140State: Optimal
     141Stripe Size: 64kB
     142Number Of Drives:2
     143Span Depth:1
     144Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
     145Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU
     146Access Policy: Read/Write
     147Disk Cache Policy: Disk's Default
    133148
     149Exit Code: 0x00
     150}}}
    134151
     152Display, disable or enable automatic rebuild on adapter 0:
     153{{{
     154server:~# megacli -AdpAutoRbld -Dsply -a0
     155
     156Adapter 0: AutoRebuild is Enabled.
     157
     158Exit Code: 0x00
     159server:~# megacli -AdpAutoRbld -Dsbl -a0
     160
     161Adapter 0: AutoRebuild is Disabled.
     162
     163Exit Code: 0x00
     164server:~# megacli -AdpAutoRbld -Enbl -a0
     165
     166Adapter 0: AutoRebuild is Enabled.
     167
     168Exit Code: 0x00
     169}}}