  • SmartArray

    v18 v19  
    105105}}}
    106106
     107== 3.2. hpacucli ==
     108
     109This tool is a proprietary one created by HP. It can do both reporting and management.
     110
     111=== 3.2.1. Quickstart guide ===
     112
     113List all controllers:
     114{{{
     115server:~# hpacucli controller all show
     116
     117Smart Array 6i in Slot 0      ()
     118}}}
     119
     120List arrays on controller in slot 0:
     121{{{
     122server:~# hpacucli ctrl slot=0 logicaldrive all show status
     123
     124logicaldrive 1 (33.9 GB, RAID RAID 1+0):  OK
     125logicaldrive 2 (136.7 GB, RAID RAID 1+0):  OK
     126}}}
     127''I don't know why it reports RAID 1+0. This is regular RAID1 arrays.''
     128
     129List physical drives on controller in slot 0:
     130{{{
     131server:~# hpacucli ctrl slot=0 pd all show status
     132
     133physicaldrive 1:0 (port 1:id 0, 36.4 GB): OK
     134physicaldrive 1:1 (port 1:id 1, 36.4 GB): OK
     135physicaldrive 1:2 (port 1:id 2, 146.8 GB): OK
     136physicaldrive 1:3 (port 1:id 3, 146.8 GB): OK
     137}}}
     138
     139
    107140[[BR]][[BR]]