| | 107 | == 3.2. hpacucli == |
| | 108 | |
| | 109 | This tool is a proprietary one created by HP. It can do both reporting and management. |
| | 110 | |
| | 111 | === 3.2.1. Quickstart guide === |
| | 112 | |
| | 113 | List all controllers: |
| | 114 | {{{ |
| | 115 | server:~# hpacucli controller all show |
| | 116 | |
| | 117 | Smart Array 6i in Slot 0 () |
| | 118 | }}} |
| | 119 | |
| | 120 | List arrays on controller in slot 0: |
| | 121 | {{{ |
| | 122 | server:~# hpacucli ctrl slot=0 logicaldrive all show status |
| | 123 | |
| | 124 | logicaldrive 1 (33.9 GB, RAID RAID 1+0): OK |
| | 125 | logicaldrive 2 (136.7 GB, RAID RAID 1+0): OK |
| | 126 | }}} |
| | 127 | ''I don't know why it reports RAID 1+0. This is regular RAID1 arrays.'' |
| | 128 | |
| | 129 | List physical drives on controller in slot 0: |
| | 130 | {{{ |
| | 131 | server:~# hpacucli ctrl slot=0 pd all show status |
| | 132 | |
| | 133 | physicaldrive 1:0 (port 1:id 0, 36.4 GB): OK |
| | 134 | physicaldrive 1:1 (port 1:id 1, 36.4 GB): OK |
| | 135 | physicaldrive 1:2 (port 1:id 2, 146.8 GB): OK |
| | 136 | physicaldrive 1:3 (port 1:id 3, 146.8 GB): OK |
| | 137 | }}} |
| | 138 | |
| | 139 | |