| 107 | == 3.2. hpacucli == |
| 108 | |
| 109 | This tool is a proprietary one created by HP. It can do both reporting and management. |
| 110 | |
| 111 | === 3.2.1. Quickstart guide === |
| 112 | |
| 113 | List all controllers: |
| 114 | {{{ |
| 115 | server:~# hpacucli controller all show |
| 116 | |
| 117 | Smart Array 6i in Slot 0 () |
| 118 | }}} |
| 119 | |
| 120 | List arrays on controller in slot 0: |
| 121 | {{{ |
| 122 | server:~# hpacucli ctrl slot=0 logicaldrive all show status |
| 123 | |
| 124 | logicaldrive 1 (33.9 GB, RAID RAID 1+0): OK |
| 125 | logicaldrive 2 (136.7 GB, RAID RAID 1+0): OK |
| 126 | }}} |
| 127 | ''I don't know why it reports RAID 1+0. This is regular RAID1 arrays.'' |
| 128 | |
| 129 | List physical drives on controller in slot 0: |
| 130 | {{{ |
| 131 | server:~# hpacucli ctrl slot=0 pd all show status |
| 132 | |
| 133 | physicaldrive 1:0 (port 1:id 0, 36.4 GB): OK |
| 134 | physicaldrive 1:1 (port 1:id 1, 36.4 GB): OK |
| 135 | physicaldrive 1:2 (port 1:id 2, 146.8 GB): OK |
| 136 | physicaldrive 1:3 (port 1:id 3, 146.8 GB): OK |
| 137 | }}} |
| 138 | |
| 139 | |